BOP Control Hoses

API 16D BOP control hoses (BOP hydraulic control lines) used for blow-out prevention systems are manufactured with superior components to operate withstand tough crisis oilfield conditions. These hoses are designed to hold full working pressure and allow continued operation of the BOP control systems ever in the harshest of fires.

BOP control hoses feature in high pressure resistance, high temperature resistance and fire resistance. Specified standard API 16D, blowout preventer hoses are ideally suited for high pressure hydraulic applications for drilling well control equipments, and capable of containing the hose rated working pressure in a flame temperature of 1300°F (700°C) for a 5-minute period.

 

BOP Hose Construction:

Tube: oil resistant synthetic rubber;

Reinforcement: 4 or 6 high tensile steel wire spirals;

Cover: oil and fire resistant synthetic rubber (5-minutes at 1300°F);

Operating temperature: -40°C to +121°C (-40°F to +249.8°F);

Operating pressure: 5000psi (35MPa);

Hose diameter: 6mm to 51mm;

Hose length: up to 90ft

 

ID (in) OD (in) WP (Psi) Min. Bend Radius(in) Weight (kg/m) Max. Length(m)
1/4 6 5000 4 0.66 100
3/8 10 5000 55 0.77 100
1/2 13 5000 7 0.98 100
3/4 19 5000 9.5 1.64 60
1 25 5000 12 2.62 60
1 1/4 32 5000 16.5 3.94 60
1 1/2 38 5000 20 4.59 60
2 51 5000 2 8.52 60

 